Medical Waste Boxes, Bags and Containers
Packaging for hazardous medical waste: rigid sharps containers from 0.4 to 12 litres, cardboard incineration boxes with a yellow liner from 7.5 to 40 litres, yellow Biohazard bags of 20–300 litres, boxes and containers for anatomical, liquid and cytotoxic waste, and body bags. Below are all the products (34), with prices from 2.60 lei.
You can change this from “Sort”.
What the Romanian rules require: colours, pictogram, filling
The technical norms on the management of waste from medical activities, approved by Romanian Ministry of Health Order no. 1226/2012, set out, among other things:
- the colour code: yellow for hazardous medical waste and black for non-hazardous waste (art. 14), and the “Biological hazard” pictogram on infectious waste packaging (art. 15);
- sharps (needles, syringes with needles, IV cannulas, scalpel blades) are collected in rigid plastic containers with a special lid, openings for detaching needles and blades, a handle and temporary and permanent closure; for infectious waste the container is yellow (art. 8, 17 and 18);
- infectious waste that is not sharp (swabs, dressings, gloves, infusion sets with tubing) goes into cardboard boxes with a yellow polyethylene liner or into yellow bags; the bag is 50–70 µm thick and is filled to at most three quarters (art. 8 and 16);
- anatomical waste is collected in rigid cardboard boxes with a polyethylene liner or in rigid plastic boxes with a tight lid, marked yellow, and is disposed of by incineration (art. 22).
The packaging must show the type of waste, the capacity, the maximum fill line, the start date of use, the date of final filling and the UN marking for ADR transport (art. 16 and 18).
Which packaging for which waste
| Waste | Packaging in this category | Capacities |
|---|---|---|
| Sharps | yellow rigid PRIMA containers (ADR); Klintensiv Biosafe Line polypropylene containers with a needle-removal system | 1, 3, 5, 7 and 12 l; 0.4–12 l |
| Infectious, non-sharp | cardboard incineration boxes with a yellow Biohazard liner: PRIMA sold individually, Klintensiv in sets of 10 | 7.5–40 l |
| Infectious, in lidded bins | yellow ADR Biohazard bags, 50–60 µm, 50 per pack | 20, 40, 60, 90, 120, 240 and 300 l |
| Anatomical | cardboard boxes with a yellow liner (PRIMA, with a red band, and Klintensiv); rigid yellow polypropylene containers with a tight lid | 7.5–40 l; 30, 50 and 60 l |
| Tissue and plasma samples | rigid polypropylene containers with a tight lid, for collection and transport | 60 ml – 3 l |
| Laboratory liquids | reusable containers with a screw cap | 5, 10 and 20 l |
| Cytotoxic (chemotherapy) | polypropylene container with double closure | 5.4 l |
Choose the capacity according to the amount of waste produced between two collections (art. 16). For autoclave decontamination there are transparent bags resistant to 134 °C under autoclavable bags. The products are grouped under boxes and bags, plastic containers and body bags, rated for 130 and 180 kg, with a zip and 4 handles.
How long waste may be stored
In medical facilities, infectious waste may be stored temporarily for at most 48 hours or, in a space kept constantly below 4 °C with automatic temperature monitoring, for at most 7 days. Medical practices may store it for at most 7 days, also below 4 °C. Transport and final disposal must not exceed 24 hours (art. 34).
For the right container for each waste category, labeling and how long infectious waste may be kept in the practice, read the guide Medical waste in the practice and Order 1226/2012.
Frequently asked questions
What colour must medical waste containers be?
Yellow for hazardous waste and black for non-hazardous waste, under art. 14 of the norms approved by Romanian Ministry of Health Order no. 1226/2012. Infectious waste packaging carries the “Biological hazard” pictogram.
How long can a medical practice keep infectious waste?
At most 7 days, at a temperature kept constantly below 4 °C (art. 34(2)). In other medical facilities the limit is 48 hours, or 7 days in a space cooled below 4 °C with automatic temperature monitoring.
How full can the yellow bag be?
At most three quarters of its volume (art. 16(3)). For boxes and containers, the norms require the maximum fill line to be marked on the label (art. 16 and 18).
Which container do I use for needles and blades?
A rigid plastic container with a lid that allows temporary and permanent closure. This category has yellow PRIMA containers of 1–12 l and Klintensiv Biosafe Line containers of 0.4–12 l, the latter with a built-in needle and blade removal system.
What are the yellow boxes with a red band for?
For anatomical waste that is not sharp, according to the product sheet. They have a 50–70 µm yellow polyethylene liner inside and are disposed of by incineration.