Instrument Sterilization: Autoclaves, Pouches and Indicators
This category brings together products for sterilizing instruments in medical and dental practices, clinics and laboratories: Class B autoclaves, water distillers and sealing machines, pouches and reels for autoclaves and dry-heat (Pupinel) sterilizers, chemical and biological indicators, Bowie-Dick and Helix tests, and autoclavable waste bags. The equipment is from Euronda, Melag, Cefla, Woson and Enbio. Prices start at 7.62 lei, and there are 65 products in total.
You can change this from “Sort”.
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 13.423,48 lei |
| 5+ | 5% | 13.146,71 lei |
| 10+ | 7% | 12.869,93 lei |
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 38.905,01 lei |
| 5+ | 5% | 38.102,84 lei |
| 10+ | 7% | 37.300,68 lei |
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 13.273,33 lei |
| 5+ | 5% | 12.999,65 lei |
| 10+ | 7% | 12.725,97 lei |
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 25.145,94 lei |
| 5+ | 5% | 24.627,46 lei |
| 10+ | 7% | 24.108,99 lei |
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 26.079,98 lei |
| 5+ | 5% | 25.542,25 lei |
| 10+ | 7% | 25.004,51 lei |
| Cant. | Discount | Price |
|---|---|---|
| 2+ | 3% | 30.177,56 lei |
| 5+ | 5% | 29.555,35 lei |
| 10+ | 7% | 28.933,13 lei |
What you will find in each subcategory
| Subcategory | Products |
|---|---|
| Autoclaves and sterilization equipment | Class B autoclaves from Woson, Euronda, Melag and Enbio; water distillers and the Melag MELAdem 40 demineralization system; Melag, Cefla and Euronda sealing machines; the Cefla Tethys H10 Plus instrument washer-disinfector and the Euronda EuroSafe Smart ultrasonic unit |
| Sterilization pouches | self-sealing pouches for steam and ethylene oxide in eight sizes, up to 250×400 mm; flat reels 50–400 mm × 200 m and gusseted reels; kraft paper pouches for dry heat |
| Dry-heat (Pupinel) sterilization | nylon pouches 51, 76 and 102 × 254 mm, 100 per pack, and reels 50, 76 and 102 mm × 30.5 m |
| Indicators and accessories | 19 mm × 50 m indicator tapes for steam, ethylene oxide and dry heat, indicator labels, Class 4, 5 and 6 strips, Bowie-Dick and Helix tests, biological indicators, a 500 W sealing machine |
| Autoclavable bags | transparent polyethylene bags with the biohazard symbol, 27, 45, 68 and 100 l, resistant to 134 °C |
Autoclave or dry heat
In Romanian healthcare facilities, the technical norms on cleaning, disinfection and sterilization approved by Health Ministry Order no. 1761/2021 recommend pressurized steam for devices that can withstand it and allow dry-heat sterilization (hot-air oven, Pupinel) only in microbiology laboratories. The autoclaves in this category are all Class B, with programmes and test cycles described in each model's product sheet. For hot-air sterilizers there are nylon pouches and reels, kraft pouches and dry-heat indicator tape.
How to check each cycle
The norms (Art. 58) divide indicators into physical (the pressure, time and temperature on the sterilizer's chart), chemical and biological. The chemical indicators in this category, by type:
| Type | What it shows | In this category |
|---|---|---|
| Type 1, external | exposure to the process: distinguishes processed from unprocessed packs | indicator tapes, 29×28 mm double-adhesive labels for steam (pink → brown) and for plasma (pink → yellow), indicators printed on pouches |
| Type 2 | steam penetration: the Bowie-Dick test, and the Helix test for lumened devices | Bowie-Dick test; Helix test with silicone tube and strips |
| Type 4, multi-parameter | one or more cycle parameters; the norms require them in every pack for plasma and formaldehyde sterilization | Class 4 steam strips, single or double, 250 per pack |
| Type 5, integrators | all parameters (pressure, time, temperature); the norms require them for every pack, container or load for steam and ethylene oxide | Class 5 strips, 70×20 mm and double 140×20 mm, integrators without adhesive (200 pcs) or self-adhesive (250 pcs) |
You will also find Class 6 steam strips and Bionova BT20 biological indicators with Geobacillus stearothermophilus spores for steam cycles at 121–134 °C; according to the product sheet, the vial is incubated at 60 °C and the result is read within 24 hours at most. Indicator and biological test results are entered in the sterilization log (Art. 66).
How long instruments stay sterile
Under Art. 59 of the same norms, items packed in paper or in sealed paper-plastic pouches stay sterile for two months from sterilization, provided the packaging is intact, unless the manufacturer specifies a different period. For rigid reusable containers with a filter, the manufacturer's stated period applies. Once opened, a kit is used only once, for a single patient.
Before packing, instruments are cleaned and disinfected (see instrument disinfectants). Stainless steel boxes, drums and baskets are under instrument boxes and trays, and containers for sharps and infectious waste under infectious waste. Shipping is free over 500 lei, for parcels up to 9 kg.
For the difference between disinfection and sterilization, autoclave cycles B, N and S, indicators and how long a wrapped instrument stays sterile, read the guide Sterilization or disinfection? Autoclaves, pouches and indicators.
Frequently asked questions
Which autoclaves are available?
Only Class B autoclaves: Woson Classic and Touch (23 l), Euronda E8 and E10 (24 l), Melag Vacuclave 323 (23 l, in a set with the MELAdem 40 demineralization system) and Enbio S. For autoclave water there are Euronda, Cefla and Melag distillers.
Can instruments be sterilized in a Pupinel?
In Romanian healthcare facilities, the norms approved by Health Ministry Order no. 1761/2021 allow dry-heat sterilization (hot-air oven, Pupinel) only in microbiology laboratories. The recommended method is pressurized steam, if the medical device can withstand it.
How do I check steam penetration in the autoclave?
With the Bowie-Dick test or, for lumened devices, the Helix test. The Bowie-Dick test in this category turns from blue to dark green when steam has penetrated; if it stays blue, sterilization is not complete.
Which chemical indicator goes in every pack?
For steam and ethylene oxide sterilization, the norms require Type 5 integrators for every pack, container or load. This category has single and double Class 5 strips and self-adhesive integrators. Type 4 indicators are required for plasma and formaldehyde sterilization.
How long do instruments stay sterile in pouches?
Two months from sterilization for paper and sealed paper-plastic pouches, provided the packaging is intact, unless the manufacturer states a different period (Art. 59 of the norms approved by Order no. 1761/2021). Once opened, a kit is used only once, for a single patient.